In this plane-strain validation the Mohr-Coulomb plasticity law
is used to calculate the bearing capacity of a foundation.
The foundation is symmetric, so that only half of the problem is analyzed.
The width of (half of) the foundation is
.
The size of the soil domain is taken to be
by
.
The Young's modulus of the soil is
and the Poisson
ratio is
.
For the Mohr-Coulomb law,both the yield rule angle is
,
and the cohesion is
.
At the bottom of the domain, all displacements are assumed to be fixed.
At the left edge (the symmetry axis) and at the right edge, the horizontal
displacement is fixed while the vertical displacement is free.
The classical solutions from Prandtl, Coulomb and Terzaghi give for the maximal
average pressure
at the foundation values in the
range
up to
.
To get the same order of accuracy as in the classical solutions, a coarse mesh with 64 quadratic elements is used.
The foundation is prescribed a downward velocity of
in the calculation.
With time steps of
the solution is advanced up to time
.
First the deformed mesh at time
is plotted below.
Secondly, the development for the average pressure at footing over time is plotted
The maximum value of average pressure is near
.
TochnogProfessional